8.5.16. Conveyor bottom

1. Remove the Hopper Plate. (See 8.5.14.)
2. Remove the 2 screws.
3. Remove the Conveyor bottom.

8.5.17. USR SENSOR Board

1. Remove the Conveyor bottom. (See 8.5.16.)
2. Remove the screw, and then disconnect the connector.

8.5.18. DFP Pressure Motor

1. Remove the Left Cover. (See 8.5.10.)
2. Remove the Conveyor bottom. (See 8.5.16.)
3. Remove the USR SENSOR Board. (see 8.5.17.)
4. Remove the UL Tape.
5. Remove the connector from □ Hole.
6. Remove the screw(a) and 4 screws(b) on the Reinforcement
Plate.