8.5.30. Ionizer L and Ionizer R

1. Remove the Drive Roller 2. (See 8.5.29.)
2. Remove the 2 screws(a) (1 from each Ionizer).
3. Remove the 2 screws with ground-lugs (1 from each Ionizer).
4. Remove the 8 clampers.
5. Pull the Ionizer L and Ionizer R.
6. Remove 2 clampers.
7. Disconnect the connector.
8.5.31. Drive Roller 1R,1L (KV-S5076H only)
1. Remove the Left Cover. (See 8.5.10.)
2. Remove the Drive Belt. (See 8.5.12.)
3. Remove the Hopper Plate Assembly. (See 8.5.14.)
4. Remove the Conveyor bottom. (See 8.5.16.)