Rinnai c199i Installation And Operation Manual page 62

Hide thumbs Also See for c199i:
Table of Contents

Advertisement

Available languages

Available languages

Code
Definition
19
Electrical Grounding
25
Condensate Trap is full
31
Burner Sensor
Outgoing Water
32
Temperature Sensor
Heat Exchanger Outgoing
33
Temperature Sensor
Outside Temperature
41
Sensor
Inlet Water Temperature
51
Sensor
Modulating Solenoid Valve
52
Signal
57
Burner
58
Secondary heat exchanger
61
Combustion Fan
65
Water Flow Control
70
PC Board
71
Solenoid Valve Circuit
72
Flame Sensing Device
73
Burner Sensor Circuit
Scale Build-up in Heat
LC #
Exchanger (when checking
(LC0,
maintenance code history,
LC1,
"00" is substituted for
LC2,...)
"LC")
Maintenance has been
FF
performed
No
Nothing happens when
code
water flow is activated.
62
Remedy
licensed
professional
Check all components for electrical short.
only
Check condensate trap and drain line for blockage.
Replace condensate trap.
Measure resistance of sensor.
Replace sensor.
Check sensor wiring for damage.
Measure resistance of sensor.
Clean sensor of scale build-up.
Replace sensor.
Check modulating gas solenoid valve wiring harness for loose or damaged terminals.
Measure resistance of valve coil.
Contact a licensed professional.
licensed
There is scale build up in the secondary heat exchanger and it needs to be flushed to prevent
professional
damage. Refer to the flushing instructions in the manual. Hard water must be treated to
only
prevent scale build up or damage to the heat exchanger.
Ensure fan will turn freely.
Check wiring harness to motor for damaged and/or loose connections.
Measure resistance of motor winding.
The water flow control valve has failed to close during the bath fill function. Immediately turn
off the water and discontinue the bath fill function. Contact a licensed professional to service
the appliance.
Check PC board DIP switches for correct position.
Check the connection harness at the connection on the PC board.
Replace PC board.
Replace the PC Board.
Replace the PC Board.
Check sensor wiring and PC board to be sure that they have not been damaged.
Replace sensor.
LC0~LC9 indicates that there is scale build up in the heat exchanger and that the heat
exchanger needs to be flushed to prevent damage. Refer to the flushing instructions in the
manual. Hard water must be treated to prevent scale build up or damage to the heat
exchanger.
To operate the water heater temporarily until the heat exchanger can be flushed, push the On/
Off button on the temperature controller 5 times. Repeated LC codes will eventually lockout
the water heater.
Please call Rinnai technical department.
Indicates a licensed professional performed maintenance or corrected an issue.
Clean inlet water supply filter.
On new installations ensure hot and cold water lines are not reversed.
Verify you have at least the minimum flow rate required to fire unit.
Check for cold to hot cross over. Isolate circulating system if present. Turn off cold water to the
unit, open pressure relief valve; if water continues to flow, there is bleed over in your plumbing.
licensed
Verify turbine spins freely.
professional
Measure the resistance of the water flow control sensor.
only
If the display is blank and clicking is coming from the unit, disconnect the water flow servo
motor (GY, BR, O, W, P, BL, R). If the display comes on replace the water flow servo motor.
C199 Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C199eRuc80i, ruc98i ru80e, ru98e

Table of Contents