Summary of Contents for Rinnai RX199i

  • Page 1 ●...
  • Page 2 été vérifié selon les instructions du fabricant fournies avec la trousse. This manual applies to the following tankless water heater models: Ce manuel s'applique aux modèles de chauffe-eau sans réservoir suivants: Residential Models Commercial Models Modèles résidentiels Modèles commerciaux RX199i (REU-NB3237FF-US) CX199i (REU-NB3237FFC-US) RX180i (REU-NB2934FF-US) CX160i...
  • Page 3 For installations in Canada, the conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the CSA- B149.1, Natural Gas and Propane Installation Code. La Conversion Doit Être Effectuée Conformément Aux Exigences De L’autorité Provinciale Ayant Juridiction Et Aux, CSA B149.1, Code D’Installation Du Gaz Naturel Et Du Propane.
  • Page 4 IMPORTANT The French manual continues on page 8. (Le manuel en français continue à la page 8.) Model RX199i RX180i RX160i RX130i RXP199i RXP160i CX199i CX160i CXP199i CXP160i Minimum 15,000 15,000 15,000 15,000 Gas Consumption (Btu/h) Maximum 199,000 180,000 160,000 130,000 Minimum: 3.5 in.
  • Page 5 IMPORTANT • Confirm that the inlet gas pressure is between the minimum and maximum pressures allowed for this appliance. • If the tankless unit has recirculation capabilities, the pump does not have to be disabled when performing these steps. CAUTION •...
  • Page 6: For Your Safety Read Before Operating

    The following operating information is required by ANSI Z21.10.3. FOR YOUR SAFETY READ BEFORE OPERATING If you do not follow these instructions exactly, a fire or WARNING explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. •...
  • Page 7 Follow the section “For Your Safety Read Before Operating” in section “4.2 WARNING Gas Operating Instructions” before starting the steps below. Check operation of the tankless water heater by choosing one of the following options: • Option 1: Check operation by using a gas analyzer (recommended) •...
  • Page 8 3. Set water temperature to 120°F (49°C) or higher, and turn Figure 5 on two or three faucets or showers. “In Use” Refer to the “Tankless Water Heater Installation and Light Operation Manual” for steps on adjusting water temperature. 4. This water heater has an automatic ignition system. When the main burner is lit, the “In Use”...
  • Page 9 1. Press the “On/Off” button on the controller to start Figure 7 the unit (Figure 7). The LED display will illuminate, “In Use” the combustion fan will begin to run if water is Light flowing, and the spark will ignite the main burner. 2.
  • Page 10 IMPORTANT The French manual continues below. (Le manuel en français se poursuit ci-dessous.) Modèle RX199i RX180i RX160i RX130i RXP199i RXP160i CX199i CX160i CXP199i CXP160i Minimum 15,000 15,000 15,000 15,000 Consommation de gaz (Btu/h) Maximum 199,000 180,000 160,000 130,000 Minimum: 3.5 in. (0.87 kPa) W.C.
  • Page 11 IMPORTANT • Confirmez que la pression de gaz à l’admission se situe entre le minimum et le maximum permis pour cet appareil. • Si l'unité sans réservoir a des capacités de recirculation, la pompe n'a pas besoin d'être dé- sactivée lors de l'exécution de ces étapes. MISE EN GARDE •...
  • Page 12: Pour Votre Sécurité Lisez Avant De Mettre En Marche

    Les informations de fonctionnement suivantes sont requises par ANSI Z21.10.3. POUR VOTRE SÉCURITÉ LISEZ AVANT DE METTRE EN MARCHE AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la pré- sente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 13 Suivez la section « Pour votre sécurité, lisez avant d'utiliser AVERTISSEMENT » dans la section « 4.2 Instructions d'utilisation du gaz » avant de commencer les étapes ci-dessous. Vérifiez le fonctionnement du chauffe-eau sans réservoir en choisissant l'une des options suivantes : •...
  • Page 14 3. Réglez la température de l'eau à 120 °F (49 °C) ou plus et Figure 5 ouvrez deux ou trois robinets ou douches. Reportez-vous au « Manuel d'installation et d'utilisation du chauffe-eau Voyant sans réservoir » pour connaître les étapes de réglage de "En la température de l'eau.
  • Page 15 1. Appuyez sur le bouton « Marche/Arrêt » du contrôleur Figure 7 pour démarrer l'appareil (Figure 7). L'affichage à DEL Voyant s'allumera, le ventilateur de combustion commencera à "En fonctionner si l'eau coule et l'étincelle allumera le cours brûleur principal. d'utilisa- 2.