Step
7
Heat up the brazing
parts and withdraw the
pipes connected to the
four way valve by pliers
and so on.
8
Heat up the two
portions of brazing
parts on the motor
valve and remove.
Removal Procedure
Procedure
Outdoor Unit
Points
In case that the removal seems
to be hard;
1. Remove the piping
connection part (brazing
part) which is easy to
remove and restore.
2. Cut the pipes on the main
unit by a miniature copper
tube cutter in order to make
it easy to remove.
NOTE:
Don't use a metal saw for
cutting pipes by all means
because the chips come into the
circuit.
Cautions at the restoration.
Wrap the motor valve with wet
cloth and make up water so that
the cloth will not be dried and
avoid excessive heating.
Caution
Be careful about four way
valve, pipes and so on, which
were heated up by a gas
brazing machine, so as not to
get burnt on your hands.