Power Injector System - Motorola AP7131 Installation Manual

Hide thumbs Also See for AP7131:
Table of Contents

Advertisement

Installation Guide
For a more exhaustive overview of the antennas and associated components supported by the Motorola Solutions
Access Point family, refer to the Enterprise Wireless LAN Antenna Specification Guide available at
http://supportcentral.motorolasolutions.com/support/product/manuals.do.

2.3.2 Power Injector System

The Access Point can receive power via an Ethernet cable connected to the GE1/PoE port.
NOTE
When users purchase a WLAN solution, they often need to place Access Points in obscure locations. In the past, a
dedicated power source was required for each Access Point in addition to the Ethernet infrastructure. This often
required an electrical contractor to install power drops at each Access Point location. The Power Injector merges
power and Ethernet into one cable, reducing the burden of installation and allowing optimal Access Point
placement in respect to the intended coverage area.
The Power Injector (Part No. AP-PSBIAS-1P3-AFR) is a high power POE Injector delivering up to 30 watts. The
Access Point can only use a Power Injector when connecting the unit to the Access Point's GE1/POE port. The Power
Injector is separately ordered and not shipped with an existing AP SKU.
An AP7131 and AP7131N can also be used with the 3af power injector (AP-PSBIAS-1P2-AFR). However, AP
functionality is limited when powered by an AP-PSBIAS-1P2-AFR, since the AP has Ethernet connectivity limited to
only the GE1 port.
The Motorola Solutions Access Point Power Supply (Part No. 50-14000-247R) is not included with the Access Point
and is orderable separately as an accessory. If the Access Point is providing both POE power over the GE1/POE
connection, as well as the 50-14000-247R power supply concurrently, the Access Point will source power from the
50-14000-247R supply only. Disconnecting AC power from the 50-14000-247R, causes the Access Point to re-boot
before sourcing power from the POE power injector. If the Access Point is operating using injector supplied power,
the Access Point will not automatically reboot if an AC adapter is connected. The Access Point continues to operate
with power supplied from the AC adapter without change to the Access Point's operating configuration. If using
adapter supplied power and a change to the Access Point's operating configuration is warranted (for example, if
needing to access the GE2 port), the Access Point needs to be manually rebooted by the customer.
CAUTION
Single radio model Access Points always operate using a full power
configuration. The power management configurations described in the table
below only apply to dual radio models. For detailed information on the power
management options available to the AP7131, refer to the Motorola Solutions
WiNG 5.4 Access Point System Reference Guide available at:
http://supportcentral.motorolasolutions.com/support/product/manuals.do.
The Access Point supports any standards-based compliant power
source (including non-Motorola Solutions power sources). However,
using the wrong solution (including a POE system used on a legacy
Motorola Solutions Access Point) could either limit functionality or
severely damage the Access Point and void the product warranty.