11
Feed difference
.04.16
Requirement
With the maximum stitch length set, when the balance wheel is turned, the needle and
bottom feed dog should carry out the same feed strokes.
Fig. 11 - 16
Adjust connecting rod 1 (nut 2) in accordance with the requirement.
Connecting rod towards " + + + + + " = greater needle feed stroke or
Towards
+ + + + +
- - - - -
1
" - - - - - "
= smaller needle feed stroke.
Adjustment
2
1
11 - 17