Data Is Being Lost; There Are Garbage Characters On The Monitor; The Modem Doesn't Work With Caller Id; Fax And Data Software Can't Run At The Same Time - Multitech MultiModem MT5634ZBA-V-V92 User Manual

Mt5634zba-series
Hide thumbs Also See for MultiModem MT5634ZBA-V-V92:
Table of Contents

Advertisement

Data Is Being Lost

If you are using data compression and a high speed serial port, set the serial port baud rate to two to six times
the data rate.
Make sure the flow control method you selected in software matches the method selected in the modem.
Try entering the I11 command or the &V command in command mode to display information about the last
connection, making a screen print of the connection statistics, and checking for parameters that might be
unacceptable.

There Are Garbage Characters on the Monitor

Your computer and the remote computer might be set to different word lengths, stop bits, or parities. If you have
connected at 8-N-1, try changing to 7-E-1, or vice-versa, using your communication software.
You might be experiencing line noise. Enable error correction, if it is disabled, or hang up and call again; you
might get a better connection the second time.
At speeds above 2400 bps, the remote modem might not use the same transmission or error correction
standards as your modem. Try connecting at a slower speed or disabling error correction. (With no error
correction, however, line noise can cause garbage characters.)
Try entering the I11 command or the &V command in command mode to display information about the last
connection, making a screen print of the connection statistics, and checking for parameters that might be
unacceptable.

The Modem Doesn't Work with Caller ID

Caller ID information is transmitted between the first and second rings, so if autoanswer is turned off (S0=0) or if
the modem is set to answer after only one ring (S0=1), the modem will not receive Caller ID information. Check
your initialization string, and if necessary change it to set the modem to answer after the second ring (S0=2).
Make sure that you have Caller ID service from your telephone company.
NOTE: The modem supports US Bellcore standard caller ID only.
Fax and Data Software Can't Run at the Same
Time
Communication devices can be accessed by only one application at a time. In Windows 2000 and higher, you
can have data and fax communication applications open at the same time, but they cannot use the same
modem at the same time.
Multi-Tech Systems, Inc. MT5634ZBA-Series User Guide (S000286G)
Chapter 7 – Troubleshooting
27

Advertisement

Table of Contents
loading

Table of Contents