• Protecting the connectors on the power cables in a weatherproof
housing or junction box (see manufacturer's instructions), or
• Replacing the supplied cable with one that connects directly inside
the fixture (see"Hard wiring the fixture to power" on page 14), or
• Using IP65 rated power connectors (see "Installing a plug on the
power cable" on page 16).
Hard wiring the fixture to power
P r e r e q u i s i te s
• Use Hypalon or neoprene rubber-jacket cable. The conductor size must
be 1.5 mm
• Verify that the power supply in the Exterior 600 is tapped for the local AC
voltage and frequency. The factor- supplied rating can be found on the
fixture serial number label.
• Verify that the feed cable is undamaged and rated for the current
requirements of all connected devices.
• if you have any doubts about proper installation, consult a qualified
electrician.
• Consult a qualified electrician if the Exterior 600 is to be connected
directly to building wiring. There must be a switch in the circuit to turn
power off when the fixture is not in use or is being serviced.
R e p la c in g t h e p o w e r c ab l e
1. Make sure the Exterior 600 is isolated from AC power and is cool.
2. Remove the 10 Allen screws from the rear cover plate.
3. Pull off the plate and seal.
14
2
(approx. 16 AWG) minimum.