Symptom
The signal is not displayed in black
frame insertion mode.
The setting is different from the
setting in the menu.
The function button of the
controller does not function.
The function of the function button
of the controller is different from
that of the panel display.
The blue light of the STATUS lamp
does not go off.
The Gamut Error message does
not go off.
120
Troubleshooting
Assumed causes
The signal is displayed in the interlace
display mode.
The 24P or 24PsF signal is displayed. The signal is not displayed in black frame insertion
The DVI Computer signal is displayed. The signal is not displayed in the black frame
The setting has been changed with
the function button of the controller
after setting in the menu.
The setting has been changed in the
menu after setting with the function
button.
Another function has been assigned to
the button.
The gamut error is detected.
Notification Reset is set to Manual and
the detected error information is
remained.
Remedy
Set Interlace to Off (page 67).
mode when the 24P or 24PsF signal is input.
insertion mode when the DVI Computer signal is
input.
The last setting becomes effective.
The last setting becomes effective.
See the Function Key menu (page 80) of the
Controller menu to confirm the function assigned to
the function button.
• Set Gamut Error Display to Off in the Display
Function menu (page 63).
• Set Notification Reset to Auto in the Display
Function menu (page 63).
• Press the function button that the Error Notify
Clear function is assigned in the Function Key
menu of the Controller menu (page 82).
• Set the pin of the PARALLEL REMOTE
connector that the Error Notify Clear function is
assigned in the Parallel Remote menu of the
System Configuration menu to On (page 70).
• Select Error Notify Clear in the Function Switch
menu of the Display Function menu (page 68).