Hitachi Kokusai Electric kp-f500pcl/scl Operation Manual page 19

Heartway
Table of Contents

Advertisement

(3) Data transmitted by master (control abort process)
HITACHI
Slave
(KP-F500PCL/SCL
KP-FR500PCL/SCL)
① Master sends ENQ code to slave.
② Since ACK code cannot be sent, slave sent NACK code to master.
③ Sequence is repeated 3 times in attempts to retransmit.
After receiving the 3rd successive NACK code, communications control is aborted
(4) Data transmitted by master (data error process)
HITACHI
Slave
(KP-F500PCL/SCL
KP-FR500PCL/SCL)
① Session starts when ENQ is sent from master to slave.
② Slave acknowledges by returning ACK to master.
③ Master sends data, but slave detect error (framing, over-run error).
④ Slave detects error and does not accept data.
⑤ Sequence 3 and 4 repeats, then master transfers normal data.
⑥ Slave detects normal data and returns ACK code to master to end the session.
ENQ code (05H)
NACK code (15H)
2
ENQ code (05H)
NACK code (15H)
ENQ code (05H)
NACK code (15H)
ENQ code (05H)
NACK code (15H)
ENQ code (05H)
ACK code (06H)
2
Send data (error occurs)
Send data (error occurs)
4
Send data (data normal)
ACK code (06H)
6
1
3
Master (PC)
1
3
3 second
elapse
3 second
elapse
5
Master (PC)
9