Motorola APX 5000 Service Manual page 143

Hide thumbs Also See for APX 5000:
Table of Contents

Advertisement

Disassembly/Reassembly Procedures: Ensuring Radio Submergibility
8. Remove the radio from the water container and dry the radio thoroughly. Be especially careful
to dry the area around the Vacuum Port and the battery contacts area.
9. With the Radio in an upright position and Control Top up, remove the vacuum adapter by
squeezing the release latches, and pulling the adapter down and away from the radio.
10. See
"8.10.9: Troubleshooting Leak Areas" on page
8.10.9 Troubleshooting Leak Areas
Before repairing any leak, first read all of the steps within the applicable section. This will help to
eliminate unnecessary disassembly and reassembly of a radio with multiple leaks. Troubleshoot only
the faulty seal areas listed in
multiple leaks exist, in the order listed.
NOTES:All disassembly and reassembly methods can be found in
If in the field, water is found around the battery leads, the O-ring on the Battery should be
inspected and replaced if needed.
8.10.9.1 Seal Interfaces
• If leak occurs at one or more of the seal interfaces, disassembly of the component(s) and
inspection of the interfaces to determine if there is any damage. If no damage is observed,
re-assemble the radio as directed.
• If damage has occurred, replacement parts will be needed.
8.10.9.2 Speaker Module
• If leak occurs through the Microphone Membrane (37) or the Speaker Module Seal (35),
replace these items.
• If leak occurs elsewhere on the Speaker Module (J), the module will need to be replaced.
8.10.9.3 Battery Contact Seal
• If leak occurs due to damage to the Battery Connector Seal (13), it will need to be replaced.
8.10.9.4 Back Chassis
• If leak occurs through the Microphone Boot (4), replace it.
• If leak occurs through the Color Display Lens (7), replace it.
• If leak occurs elsewhere on the Back Chassis (B/N), it will need to be replaced.
8.10.9.5 Control Top
• If leak occurs through the antenna or the Control Top Seal (22), replace it.
• If leak occurs elsewhere on the Control Top Assembly (F), it will need to be replaced.
To avoid equipment damage, keep the area inside the Battery
contact pocket is dry before assembling battery.
"8.10.8: Pressure Test (using NTN4265_)" on page 1:8-42
1:8-43.
Section 8.7.
and
Sec 1: 8-43
and, when
Section 8.9.