Pressure Test Points
The minimum supply pressure is given in the section
Specifi cations of this manual—page 20.
All piping and connections must be tested for leaks af-
ter installation or servicing. All leaks must be corrected
immediately.
When testing for leaks:
• Make sure that the appliance is turned off.
• Open the manual shut-off valve.
• Test for leaks by applying a liquid detergent or soap so-
lution to all joints. Bubbles forming indicate a gas leak.
Never use an open fl ame to check for leaks.
Correct any leak detected immediately.
The pressure test tapping locations are shown in the
fi gure at right. An internal regulator within the valve con-
trols the burner manifold pressure. The correct pressure
range is shown in the table in section Specifi cations of
this manual on page 20. The pressure check should be
made with the burner alight and at its highest setting.
See Lighting Instructions section for full operating details
on page 17.
Installation
Manifold
Test
Pressure
Pressure Testing