[9] Initialization to factory settings

Caution:
When the factory settings have been made, all user setting data, including the channel settings, are initialized.
(The adjustments done in the adjustment process mode are not initialized.) Keep this in mind when initializing these settings.
Adjustment item
1
Factory settings
After adjustments, exit the adjustment process mode.
To exit the adjustment process mode, unplug the AC power cord from the outlet to forcibly turn off the power.
When the power is turned off with the remote control, unpulug the AC power cord and plug it back in (wait apporximately 10 seconds before plug-
ging in the AC power cord).

[10] Lamp error detection

1. Function description
This LCD colour television has a function (lamp error detection) to be turned OFF automatically for safety when the lamp or lamp circuit is abnormal.
If the lamp or lamp circuit is abnormal, or some other errors happen, and the lamp error detection is executed, the following occur.
1- The main unit of television is turned OFF 5 seconds after it is turned ON. (The power LED on the front side of TV turns from green to red.)
2 - If the situation "1" happens 5 times sequentially, the power is turned on (relay is turned ON).
However, the backlight is not turned on, and then the relay is turned OFF after 5 to 6 seconds. (The power LED turns from green to red.)
2. Countermeasures
When television is turned OFF by the lamp error detection mentioned above, it enters the adjustment process with the power LED red. Entering the
adjustment process turns OFF the error detection and turns ON TV. This enables the operation check to detect errors in the lamp or lamp circuit
Check whether "L ERROR RESET" on point 7, page 10/11 of the adjustment process is 1 or more. If it is 1 or more, it indicates the lamp error detec-
tion was executed. After confirming that the lamp or lamp circuit is normal, reset the lamp error counter pushing "OK" in the R/C. After resetting
counter the label "***OK***" appears on Screen.
3. Reset standby cause error list
After confirming that the lamp error counter has been erased, select "STAND BY CAUSE RESET" on point 3, page 10/11 of the adjustment process
and select ON using the right cursor. For execute press "OK" in the R/C and the label "***OK***" appears on Screen.
Adjustment conditions
Forcibly turn off the power
(See to below caution)
Adjustment procedure
Enter the adjustment process mode.
Move the cursor to [Factory Init] on page 2/11.
Use the R/C
key to select a destination [EURO/RUSSIA/
SWEDEN]. And, press the [OK] key.
"EXECUTING..." appears and initialization starts.
After a while, "*** OK ***" appears and the setting is complete.
NOTE: Never turn the power off during initialization.
When performing factory settings (while displaying page 2 of adjustment
process), confirm that the item "Inch Setting" or the panel size displayed
in the upper right corner corresponds to each panel size.
The following settings will be back to their factory ones.
1. User settings
2. Channel data (e.g. broadcast frequencies)
3. Maker option setting
4. Password data