Change of chimney connection

The stove is delivered ready for top outlet, but may be changed to back outlet in the fol-
lowing way:
36
RAIS - Manual for RAIS Poleo II, RAIS Epoca II
Strike out the knock out plate at the rear of stove.
Remove the blanking plate and the packing, and
position them in the hovle at the top. Ensure that the
packing is positioned correctly. Screw all elements
together with the three M6 nuts.
Mount the flue collar (supplied by the dealer) and
the clamp for the upper smoke conductor with three
M6x20 cylinder screws and M6 nuts.
Mount the parts in reverse order.