Connecting the Hub

NOTE:
The following applies primarily to the K100-622H Model with included hub.
®
Hub connects to the Access Control system via Wiegand wiring. The hub requires 8–24 VDC power
The Aperio
(250mA). The hub includes three Form C relays that can be used to transmit latch bolt position status, low
battery signal, and a tamper signal. The hub connects to the cabinet lock wirelessly.
3.
CONNECT Latchbolt Position, Low
Battery, and Tamper Switch Detection
Form C relays.
NOTE 1:
The Green LED input is used to grant access to the cabinet lock. If the Green LED signal is not available
to indicate approved access, the approval input can be activated by a relay with "NO" attached to Green
LED and "C" to GND.
NOTE 2:
The Red LED input is used to indicate access denied. If the RED LED signal is not connected, the lock will
flash RED three times when a non-approved card is presented indicating loss of connection to the hub
rather than access denied. Any other codes may be reference on the LED reference card.
3080076.004, Rev. B
1.
CONNECT the Wiegand D1, D0, red and green LED signals.
2.
CONNECT 8–24 VDC and ground (250 mA).
Connecting the hub