Maintenance

FILTERS

When filters wear out, replace them with similar aluminum or
charcoal filters that have stainless steel clips. Also replace filters
damaged with punctures, bends, or broken frames.
□ Turn off the range hood and disconnect the power.
□ Remove the aluminum filter by pulling the handles or the
charcoal filter by unhooking the charcoal filter support and
sliding it out.
□ Replace with an equivalent filter, then reconnect the power.

LIGHT BULBS

When light bulbs burn out, replace them with a 25W or 35W /JDR
16, GU10 twist and lock base light bulb.
□ Turn off the range hood, disconnect it from its power
source, and ensure that the lights are cool.
□ Turn the bulb counter-clockwise and pull it out to remove it.
□ Push in the new bulb and turn it clockwise. Do not release
the bulb until you are sure the bulb has been securely
installed. Then reconnect the power.
□ If new bulbs do not operate, ensure that they are inserted
correctly.
DANGER: Turn off the power circuit breaker or the power
switch on the junction box before performing maintenance.
Touching circuitry inside the range hood while it is
energized will result in death or serious injury.
WARNING: Failure to replace worn out or damaged filters
will increase the risk of fire.
WARNING: Light bulbs can become extremely hot when
turned on. Do not touch bulbs until they are switched off
and cooled. Touching hot bulbs could cause serious burns.
13
Please contact 1-800-514-6729 for further assistance.