Installation

For top and back venting methods, refer to steps 1, 2, 3, 4, 6
For inside venting system, refer to steps 1, 3, 5, 6
1
Removing the electrical knock-out hole
WARNING: Always wear safety goggles and gloves during
installation.
□ Choose the appropriate electrical knock-out hole to remove
for your installation type. Use the top hole (1) for a top
venting installation and the back hole (2) for a back venting
installation.
□ Use a hammer and a flathead screwdriver to gently punch
out the electrical knock-out hole.
1
2
A
3
Testing the electrical connection
DANGER: Turn off the power circuit breaker or the power switch on
the junction box before installing this unit. Touching circuitry inside the
range hood while it is energized will result in death or serious injury.
DANGER: All electrical wiring must be properly installed, insulated,
and grounded. Improper insulation and grounding will result in deadly
electrical shock. Consult a qualified electrician if the grounding
instructions are not completely understood, or if doubt exists as to
whether the appliance is properly grounded.
WARNING: Attempting to install or service this unit when you do not
have the necessary technical or electrical background could result in
personal injury.
WARNING: When cutting or drilling into the wall or ceiling, do not
damage electrical wiring and other hidden utilities.
NOTE: Use copper cables and wires only. Wire sizes must conform to
the requirements of the National Electrical Code ANSI/NFPA 70 or the
CSA Standards C22.1-94, Canadian Electrrical Code part 1 and C22.2 No.
0-M91, and all local codes and ordinances.
NOTE: It is the customer's responsability to contact a qualified
electrical installer and assure that the electrical installation is adequate
and complies with the National Electrical Code, or CSA standard and all
local codes and ordinances.
NOTE: A UL listed or CSA approved conduit connector must be
provided at each end of the power supply cable (at the range hood and
at the junction box).
2

Removing the venting hole

□ Choose the venting hole to remove for your installation
type. Use the top hole (3) for a top venting installation and
the back hole (4) for a back venting installation.
□ Using a flathead screwdriver or needle nose pliers, remove
the venting hole. Be very careful not to leave any broken
pieces inside the range hood (A).
A
Observe all governing codes and ordinances warning:
- Electrical grounding is required for this range hood.
- Check with a qualified electrician if you are not sure whether the range
hood is properly grounded.
- Failure to follow electrical requirements may result in a fire.
- A fuse in the neutral or grounding circuit could result in electrical shock.
- If the hot/cold water pipe is interrupted by plastic non metallic gaskets or
other materials, DO NOT use for grounding.
- DO NOT use an extension cord or adapter plug with this appliance.
Use the power supply cable to connect the range hood (A) directly to the
junction box or circuit breaker box. Use a flexible, armoured, or non metallic
sheathed copper cable only. Never use an extension cord or adapter plug.
Connect a UL-listed or CSA-approved conduit connector to each end of the
power supply cable (at the range hood and at the junction box).
Connect the three colored wires (3) from the range hood (A) to the
corresponding wires (4) from the electrical source: black to black (live),
white to white (neutral), and green/yellow to green/yellow (ground). Use
either the top hole (1) or the back hole (2) of the range hood depending on
your installation type.
Turn the power on, and ensure that all lights and fans are operating
correctly.
Once you have tested the electrical connection, disconnect the power
supply cable and wires from the electrical source before proceeding with
the rest of the installation.
9
Please contact 1-800-514-6729 for further assistance.