Elan s86a Installation Manual page 67

Integrated multi-room a/v controller
Table of Contents

Advertisement

E L A N H O M E S Y S T E M S
Symptom
Possible Cause/s
Sense Trigger
1. Wiring;
Inputs:
Sense Inputs
Triggered
incorrectly
event fails to
connected or
occur.
incorrect type
Example: VIA!
of Sensor/
Touch Panel
faulty Sensor.
does not
2. Programming;
switch to
Sense
Camera
Inputs incorrectly
Mode.
programmed
in
VIA!TOOLS or ELANTOOLS
Zone/System
1. Wiring; bad
Trigger Outputs:
mini-cable or
Triggered
using 3.5 mm
event fails to
stereo cable
occur.
instead of
Example:
mono.
Amplifier
2. Test for
does not turn
voltage w/ Digital
ON when
Multi-
zone
Meter.
becomes
3. Programming
active.
Page Trigger
Wiring: incorrect
Inputs/Outputs:
connections
Triggered
between
event fails to
C2 and
occur.
S86A/SPP.
Example:
Volume Control
Override
does not
function
.
© ELAN Home Systems 2009 • All rights reserved.
Table 5-3 Triggers Troubleshooting Procedures
What an authorized installer can do
a. Connect a 3.5 mm mono mini cable to Sense Input. This
simulates a contact closure and should trigger the event.
b. Replace Sensor or use different type
Verify and correct programming. See VIA!TOOLS or ELANTOOLS Help file.
a. Must use MONO mini cable.
b. Replace defective cable.
Correct reading is +12 VDC.
Correct programming in VIA!TOOLS or ELANTOOLS.
See 'Communications'