Quadra-Fire 3100 MILLENNIUM Installation Manual

Quadra-Fire 3100 MILLENNIUM Installation Manual

Wood appliance automatic combustion control
Hide thumbs Also See for 3100 MILLENNIUM:

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
3100 MILLENNIUM WOOD APPLIANCE
AUTOMATIC COMBUSTION CONTROL
MODEL(S):
31M-ACC-C
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
(ACC)
R
If the information in these instructions is
not followed exactly, a fire could result
causing property damage, personal injury,
or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
Do not over-fire - If appliance or chimney connector
glows, you are over-firing. Over-firing will void
your warranty.
Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass and appliance will cause burns.
Do not touch glass until it is cooled
Use leather gloves when reloading fuel
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room
as appliance.
Alert children and adults to hazards of
high temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
flammable materials away.
Fire Risk.
For use with solid wood fuel only.
Other fuels may over-fire and generate
poisonous gases (i.e. carbon monoxide).
NOTE: To obtain a French translation of this
manual, please contact your dealer or visit
www.quadrafire.com
REMARQUE : Pour obtenir une traduction française de
ce manuel, s'il vous plaît contacter votre
revendeur ou visitez
7033-350E
WARNING
WARNING
WARNING
www.quadrafire.com
September 9, 2019

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire 3100 MILLENNIUM

  • Page 1 OWNER: Retain this manual for future reference. NOTICE: DO NOT DISCARD THIS MANUAL WARNING If the information in these instructions is not followed exactly, a fire could result 3100 MILLENNIUM WOOD APPLIANCE causing property damage, personal injury, or death. AUTOMATIC COMBUSTION CONTROL •...
  • Page 2: Table Of Contents

    B. Hearth Protection Requirements ....9 C. Clearances to Combustibles ....10 Quadra-Fire is a registered trademark of Hearth & Home Technologies. 7033-350E...
  • Page 3: Important Safety Information

    31M-ACC-C Important Safety Information A. Appliance Certification B. BTU & Efficiency Specifications Model: 3100 Millennium Wood Appliance EPA Certification 86-17 Number: Laboratory: OMNI Test Laboratories, Inc. EPA Certified Emissions: 1.9 grams per hour Report No: 0061WS066S *LHV Tested Efficiency: 78.3%...
  • Page 4: Mobile Home Approved

    31M-ACC-C C. Mobile Home Approved WARNING • This appliance is approved for mobile home installations; when not installed in a sleeping room and when an outside combustion air inlet is provided. Fire Risk • The structural integrity of the mobile home floor, ceiling, Hearth &...
  • Page 5: Getting Started

    31M-ACC-C Install Guide Getting Started A. Design and Installation Considerations B. Fire Safety Consideration must be given to: To provide reasonable fire safety, the following should • Safety be given serious consideration: • Convenience 1. Install at least one smoke detector on each floor of •...
  • Page 6: Tools And Supplies Needed

    31M-ACC-C F. Removal of Appliance from Shipping To minimize the effects of negative air pressure: • Install optional outside air kit with the intake facing Materials prevailing winds during the heating season 1. Remove box and 2x4 structural boards being careful •...
  • Page 7: Install Checklist

    31M-ACC-C G. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjuction with, not instead of, the instructions contained in this installation manual. _________________________________________________________________________________ Customer: ______________________________________________________________________________ Date Installed: ______________________________________________________________________________ Lot / Address: ________________________________________________________________________...
  • Page 8: Dimensions And Clearances

    31M-ACC-C Dimensions and Clearances A. Appliance Dimensions NOTE: Flue Collar size is 6 inch (152mm) diameter (ID) 25-1/2 in [648mm] 3-1/2 in 12-3/4 in [89mm] [323mm] 6-3/4 in [171mm] 11 in [278mm] 29-1/2 in [749mm] 15-1/8 in [383mm] 21 in [533mm] Figure 8.1 - Front View Figure 8.2 - Top View 26-5/8 in [676mm]...
  • Page 9: Hearth Protection Requirements

    31M-ACC-C B. Hearth Protection Requirements In Canada, similar floor protection must be provided 18 EMBER PROTECTION: It is necessary to install a Type I inches (457mm) in front and 8 inches (203mm) from the floor protector. sides and rear of the appliance unless the hearth pad is placed against the wall (Figure 9.2).
  • Page 10: Clearances To Combustibles

    31M-ACC-C C. Clearances to Combustibles MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS in inches (Millimeters) Note: A, C, and F Dimensions are to the center of the flue collar 3100 Millennium INSTALLATION: FULL VERTICAL SINGLE WALL PIPE 18-1/4 (464) 11-3/4 (298) 28-1/2 (724)
  • Page 11: Chimney Systems

    31M-ACC-C Chimney Systems A. Locating Your Appliance & Chimney • Consider the appliance location in order to avoid floor and ceiling attic joists and rafters. Location of the appliance and chimney will affect • Locate termination cap away from trees, adjacent performance.
  • Page 12: Chimney Termination Requirements

    31M-ACC-C B. Chimney Termination Requirements NOTICE: Locating the appliance in a basement or in Follow manufacturer’s instructions for clearance, securing a location of considerable air movement flashing and terminating the chimney (Figure 12.1 & 12.2). can cause intermittent smoke spillage from •...
  • Page 13: Chimney Height / Rise And Run

    31M-ACC-C D. Chimney Height / Rise and Run Chimney: The chimney can be new or existing, masonry or This product was designed for and tested on a 6 inch prefabricated and must meet the following minimum (152mm) chimney, 14 to 16 feet (420-480cm) high, requirements and as specified in Section 4F.
  • Page 14 31M-ACC-C Thimble Listed Termination Cap Site constructed for masonry chimney installation: Storm Collar Components A minimum length of 12 inches [305mm] (longer for thicker Flashing walls) of solid insulated factory-built chimney length constructed to UL 103 Type HT 6 inch (152mm) inside diameter.
  • Page 15: Installing Chimney Components

    Constructed to NFPA 211 Figure 15.2 H. Proper Draft To be sure that your Quadra-Fire insert burns properly, the chimney draft (static pressure) should be approximately -0.10 inches water column (W.C.) during a high burn and -0.04 inches W.C. during a low burn, measured 6 inches (152mm) above the top of the insert after one hour of operation at each burn setting.
  • Page 16: Appliance Set-Up

    31M-ACC-C Appliance Set-Up A. Outside Air Kit Installation WARNING A source of air (oxygen) is necessary in order for combustion to take place. Whatever combustion air is consumed by the fire must be replaced. Air is replaced via Fire Risk. Asphyxiation Risk. air leakage around windows and under doors.
  • Page 17: Door Handle Assembly

    31M-ACC-C B. Door Handle Assembly C. Blower (Optional) Install spring handle using a counter-clockwise motion until 1. Locate bolts supplied with the blower. the spring handle has a 2 inch clearance from bend of door 2. Align holes in mounting flange of blower with bolt holes hand rod (Figure 17.1).
  • Page 18: Mobile Home Installation

    31M-ACC-C Mobile Home Installation You must use a Quadra-Fire Outside Air Kit Part OAK-ACC CAUTION and (depending on floor installation), Part SRV7033-041 for installation in a mobile home. THE STRUCTURAL INTEGRITY OF THE MOBILE 1. An outside air inlet must be provided for combustion HOME FLOOR, WALL AND CEILING/ROOF MUST (see page 15 for installation information).
  • Page 19: Reference Materials

    31M-ACC-C Reference Materials A. Service & Maintenance Log Date of Service Performed By Description of Service September 9, 2019 7033-350E...
  • Page 20 31M-ACC-C Date of Service Performed By Description of Service 7033-350E September 9, 2019...
  • Page 21: Accessories

    ITEM DESCRIPTION COMMENTS PART NUMBER ACCESSORIES 31M-ACC-C Blower Assembly BK-ACC B. Accessories Blower, Convection - Replacement Blower 812-4900 Blower Control Box w/Switch SRV7000-194 31M-ACC-C Service Parts Component Pack 7033-051 Snap Disc Bracket Assembly SRV7033-036 Beginning Manufacturing Date: June 2017 Ending Manufacturing Date: Active Snap Disc, # 1, Convection Blower SRV230-0470 Wire Harness, Blower...
  • Page 22 CONTACT INFORMATION Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafi re.com CAUTION DO NOT DISCARD THIS MANUAL •...

Table of Contents