Troubleshooting - Xantrex XPower Pocket Inverter 175 User Manual

Table of Contents

Advertisement

7 Troubleshooting

PROBLEM: AC product will not operate, no inverter
lights are
ON
Possible cause
Battery is defective.
Loose connections.
Fuse is blown.
PROBLEM: Measured inverter output is too low.
Possible cause
Standard "average-
reading" AC voltmeter
used to measure output
voltage, resulting in an
apparent reading 5 to 15 V
too low.
Battery voltage is too low.
18
.
Remedy
Check battery and replace if
required.
Check connections.
Replace fuse (see page 20).
Remedy
Inverter's "modified sine
wave" output requires "true
RMS" voltmeter for accurate
measurements.
Recharge battery.