Norcold 8682 Repair Manual page 31

Table of Contents

Advertisement

Abnormal condition
Mode Selector set to gas, LP and
CHECK light illuminated. Refrig-
erator will not light the Burner, or
the Burner lights for a few seconds
and goes out.
Probable Cause:
A. Low input voltage
B. LP turned off at main tank
or shut-off valve
C. LP pressure not adjusted
correctly
D. Air in the LP gas lines
E. Gas valve did not open
F. No sparks to the Burner
G. Electrodes not adjusted cor-
rectly
H. Orifice & Burner obstructed
I. Loose or corroded connec-
tion
J. Defective Ignition Module
Abnormal condition
Mode Selector set to gas, LP and
CHECK light Illuminated, and the
Flame is Burning
Probable Cause:
A. Low input voltage
B. Corrosion in the cable con-
nectors
C. Moisture on the Eyebrow
board
D. Defective Ignition Module
E. Defective cable
Abnormal Condition
Mode Selector set to AC ELEC,
AC and CHECK lights are illumi-
nated.
Probable Cause:
A. Defective fluorescent light
(1) Turn off all fluorescent
lights. If the CHECK
light goes out, one of the
fluorescent lights is de-
fective.
(2) Replace the light or wire
the refrigerators 12 volt
DC input to the battery
B. Corrosion in the cable con-
nectors
C. Defective Power Supply
D. Defective cable
Figure 5.66
Figure 5.67
5-31

Advertisement

Table of Contents
loading

This manual is also suitable for:

86838652866286638653

Table of Contents