21. Check for 12 volts across the
DC heater fuse as shown by
Figure 5.61. If 12 volts is not
measured, the fuse is blown
and must be replaced.
WARNING
NEVER OVERFUSE A CIRCUIT.
REPLACE BLOWN FUSE WITH
EXACT
REPLACEMENT
CATED BY NORCOLD. OVER-
FUSING OF A CIRCUIT CAN RE-
SULT IN A FIRE.
22. If 12 Volts DC is present, check
resistance of the DC Heater
element as shown in Figure
5.62. If not within allowable speci-
fication (see Technical Data
section), replace heater.
INDI-
Figure 5.61
Figure 5.62
DC Heater Fuse Check
Blue and White Leads
Heater Resistance Check
5-29
Standard Heater
(early version)
Horizontal Burner Type
(current version)