OPERATING LIMITS - ALL
MODELS
AC Mode: 132 VAC Max., 108
VAC Min.
15. 4 VDC Max., 10.5
VDC Min.
DC Mode: 15.4 VDC Max., 11.5
VDC Min.
Gas Mode: 11" W.C.
15.4 VDC Max., 10.5
VDC Min.
MODELS 8652, 8653

RATINGS

1200 Btu/Hr Input
LP Gas Mode:
11" W.C.
LP14 Orifice
12 Volts DC control voltage
AC Mode:
110 Volts AC, 170 Watts
12 Volts DC control voltage
DC Mode (3-Way only):
12 Volts DC
MODELS 8662, 8663
RATINGS
1450 Btu/Hr Input
LP Gas Mode:
11" W.C.
LP16 Orifice
12 Volts DC control voltage
AC Mode:
110 Volts AC, 300 Watts
12 Volts DC control voltage
DC Mode (3-Way only):
12 Volts DC
General Information and Specification
MODELS 8682,8683
RATINGS
1500 Btu/Hr Input
LP Gas Mode:
11" W.C.
LP16 Orifice
12 Volts DC control voltage
AC Mode:
110 Volts AC, 300 Watts
12 Volts DC control voltage
DC Mode (3-Way only):
12 Volts DC
CURRENT DRAWS - 8652, 8653
Automatic ignition - Less than 250 milliamps or .25 amps
AC Heating Element - 1.5 amps at 110 Volts AC
DC Heating Element - 9.2 amps at 12 Volts DC
CURRENT DRAWS - 8662, 8663, 8682, 8683
Automatic ignition - Less than 250 milliamps or .25 amps
Humidity Heater - 240 milliamps or .24 amps
Interior Lamp (when door open) - 900 milliamps or .90 amps
AC Heating Element - 2.7 amps at 110 Volts AC
DC Heating Element - 13.8 amps at 12 Volts DC
OPERATION WHERE THESE SPECIFICATIONS ARE EXCEEDED MAY
CAUSE DAMAGE AND WILL VOID REFRIGERATOR WARRANTY.
1.7 amps at 120 Volts AC
10.7 amps at 14 Volts DC
2.9 amps at 120 Volts AC
16.1 amps at 14 Volts DC