29. Check the alignment of the
electrodes as shown in Figure
5.34.
30. Check for a loose wire con-
nection at the electrodes and
Ignition Module. If all checks
are proper and still no spark at
Burner, proceed to next step.
31. Check the Sense and Ignition
electrodes shown in Figure
5.35 for a short to ground.
A. Turn the Mode Selector to
OFF.
B. Set the Volt-Ohm-meter to
the Rx10K scale
C. Disconnect the wires to the
electrodes
D. Check
the
continuity
ground
E. Any needle movement indi-
cates a defective electrode
and it must be replaced.
32. Reconnect the electrodes and
set the Mode Selector back to
gas.
33. Make sure the main line LP
gas is on as shown in Figure
5.36.