2. Remove the wire connections
from the Power Supply terminals.
3. Disconnect the cable from the
Power Supply.
4. Remove the Power Supply
cover to gain access to the
Power Supply.
5. Reconnect the DC supply wires
to terminals J-4(-) and J-5(+).
6. Check for 12 volts DC at the 3
amp fuse as shown in Figure
5.24.
7. If you do not have 12 volts as
shown. Replace the 3 amp
fuse.
NEVER OVERFUSE A CIRCUIT.
REPLACE BLOWN FUSE WITH
EXACT REPLACEMENT INDICAT-
ED BY NORCOLD. OVERFUSING
OF A CIRCUIT CAN RESULT IN A
FIRE.
8. Reconnect the cable to the
Power Supply. Set the Mode
Selector to OFF as shown in
Figure 5.29.
9. Be sure the storage switch is
in the down position as shown
in Figure 5.25. (original and
third versions)
10. Using the volt meter, check for
12 volts DC at the locations 1,
2, 3 shown in Figure 5.26.
11. If you do not have 12 volts
(10.5 Volts min.), replace the
Power Supply.
Note:
A two way Power Supply will not
have the D-4 diode, and the origi-
nal version diodes will be D-6 and
D-7.
12. Remove the screws shown in
Figure 5.27, and pull the Eye-
brow assembly away from the
refrigerator as shown.
Figure 5.25
Storage Switch Location
Figure 5.26
12 Volt DC Voltage Check
Figure 5.27
Eyebrow Removal