14. Remove the Eyebrow board
from the Eyebrow as shown
by Figure 5.48.
15. Set the Mode Selector switch
to the OFF position as shown
by Figure 5.49.
Note:
These checks cannot be per-
formed unless the Eyebrow board
has the LED as shown.
16. Connect a volt meter as
shown in Figure 5.49.
17. You should measure 12V DC
at the emitter of Q11. If 12
volts is not indicated, replace
the wire harness.
18. Set the Mode Selector to gas,
the voltage should now drop to
5.6 volts DC. If it does not, re-
place the Eyebrow board.
19. Set the Mode Selector switch
to OFF.
20. With the volt meter's negative
lead at D12, as shown in Figure
5.49, check the switch terminals
shown in Figure 5.50.
21. You must have 12 volts on all
the terminals shown. If you do
not have 12 volts the cable is de-
fective and must be replaced.
22. Set the Mode Selector switch
(es) to AC ELECTRIC Mode.
Use the Volt meter (with nega-
tive lead still connected per Fig-
ure 5.49) and check Points B, D
and E as shown in Figure 5.50.
You should measure approxi-
mately 2 Volts DC. If not, re-
place the Eyebrow Board.
Figure 5.48
Eyebrow Board Removal
Figure 5.49
12 Volt DC Check
Figure 5.50
Control Voltage Check
5-24