Selection Type; Measuring Range; Sp Signal - Intec MGC2-16 User Manual

Multi-point controller
Table of Contents

Advertisement

PolyGard
Multi-Point Controller
®
User Manual - MGC2-16
3.6.2

Selection Type

Assign sensor Type to active transmitters.
Symbol
Description
SP 01
Sensor point
NH3
Type
1
Range Recommendations for PolyGard sensors
2
During oxygen measurement falling signal!
3.6.3

Measuring range

The measuring range can be defined from 10 to 10000. The measuring ranges in the above table are typical and
only recommendations. For actual ranges see the sensor manufacturing specifications.
The measuring range must agree with the signal (4 to 20 mA) for active transmitters.
(4 mA = Display=0, 20 mA = Display Measuring range = max. point)
3.6.4

SP Signal

Gas transmitter with electro-chemical or catalytic bead sensors are linear for gas concentration proportional to the
4 to 20 mA signal.
Semiconductor gas sensors that are not linear and have a (exponential) signal. This signal is non-linear 4 to 20
mA signal from the gas transmitter.
The Controller MGC2 has the capability to monitor both types of gas transmitters, and other linear 4-20 mA
sensors. The type of signal is defined in this menu.
Symbol
Description
SP 01
Sensor Point
Linear
SP Signal
Polygard® is a registered trademark of MSR
Customer Services (858) 578-7887 & (888) GO INTEC
INTEC Controls, 12700 Stowe Dr., Suite 100, Poway, CA 92064
Setting
Type
Status
CO
Carbon monoxide
Ex
Combusible gas
NO
Nitrogen oxide
NO
Nitrogen dioxide
2
NH
Ammonia
3
O
Oxygen
2
CO
Carbon dioxide
2
SO
Sulphur dioxide
2
H
S
Hydrogen sulphide
2
CL
Chlorine
2
ETC
Ethylene oxide
VOC
Air quality
R401
Refrigerant gas
NH
R402
Refrigerant gas
3
R408
Refrigerant gas
R409
Refrigerant gas
R404
Refrigerant gas
R416
Refrigerant gas
R502
Refrigerant gas
R410
Refrigerant gas
R411
Refrigerant gas
R11
Refrigerant gas
R123
Refrigerant gas
R134
Refrigerant gas
R22
Refrigerant gas
Temperature
TEM
RH
Humidity
Setting
Function
Status
Selection SP No.
linear
= Transmitter with linear Output signal
linear
not linear = Transmitter with non linear Output signal (future).
Fax (858) 578-4633 & (888) FX INTEC
www.inteccontrols.com
Page 16
Unit
ppm
%LEL
ppm
ppm
ppm
2
%V/V
ppm
ppm
ppm
ppm
ppm
%
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
°C
% RH
Specification subject to change without notice.
Measuring
1
range
0 – 300
0 – 100
0 – 50
0 – 25
0 – 300
0 – 25
0 – 2000
0 – 100
0 – 200
0 – 100
0 – 20
0 – 100
0 – 2000
0 – 2000
0 – 2000
0 – 2000
0 – 300
0 – 300
0 – 300
0 – 300
0 - 300
0 – 300
0 – 300
0 – 300
0 – 300
0 – 150
0 – 100
MGC2-16