Maximum working pressure: 3500 PSI – 241 BAR – 24.1 Mpa
The following instructions provide the necessary information for the proper operation and preventative maintenance of the
BINKS
3500 PSI Airless Spray Gun. It is the customer's responsibility to have all operators and service personnel
read and understand this manual. Please read and understand all information in this document in order to safely operate your
new spray gun.
SPECIFICATIONS:
Maximum Fluid Pressure: 3500 psi / 241 bar
Gun Body: Forged Aluminum
Fluid Path: Anodized Aluminum
Fluid Inlet: ¼-18 NPS (m)
Gun Weight: 580 g
WARNING
EYE HAZARD: Failure to wear safety glasses with side shields could
result in serious injury or blindness. All operators and bystanders must
always wear safety glasses with side shields that conform to ANSI
Standard Z87.1 or European Norm 156.
WARNING
HAZARD: INjECTION INjuRY – a high pressure stream produced by
this equipment can pierce the skin and underlying tissues, leading to
a serious injury and possible amputation. See a physician immediately.
DO NOT TREAT AN INjECTION INjuRY AS A SIMPLE CuT! Injection
can lead to amputation. See a physician immediately.
SAFETY PRECAuTIONS :
KEEP CLEAR OF NOZZLE. Do not exceed maximum working pressure of
3500 PSI ( 241 BAR, 24.1 Mpa). The maximum operating range of the gun is
3500 PSI/241 BAR fluid pressure.
NEVER Aim the gun at any part of the body.
NEVER Allow any part of the body to touch the fluid stream. DO NOT allow
body to touch a leak in the fluid hose.
3500 PSI Airless Spray Gun
For trained, professional use only!
Models 1108-3500-2 & 1108-3500-4
!! SAFETY, OPERATING AND MAINTENANCE
INSTRuCTIONS INSIDE!!
Read all warnings and
operating information inside
SAVE THIS MANuAL FOR FuTuRE REFERENCE
Contact your local Binks representative for
additional copies of this manual
NEVER Put hand in front of the gun. Gloves will not provide protection
against an injection injury.
ALWAYS lock the gun trigger, shut the pump off, and release all pressure
before servicing, cleaning the tip or guard, changing the tip, or leaving
unattended. Pressure will not be released by turning off the motor. The
PRIME/SPRAY valve must be turned to PRIME to relieve the pressure. Refer
to the PRESSURE RELIEF PROCEDURE described in the pump manual.
ALWAYS Keep the tip guard in place while spraying. The tip guard provides
some protection, but is mainly a warning device.
ALWAYS Remove the spray tip before flushing or cleaning the system.
The paint hose can develop leaks from wear, kinking, and abuse. A leak
can inject material into the skin. Inspect the hose before each use.
NEVER Use a spray gun without a trigger lock and trigger guard in place
and in good working order.
All accessories must be rated at 3500 PSI (241 BAR) or higher. This
includes spray tips, guns, extensions, and hose.
NOTE TO PHYSICIAN:
Injection into the skin is a traumatic injury. It is important to treat the
injury as soon as possible. DO NOT DELAY treatment to research
toxicity. Toxicity is a concern with some coatings injected directly into
the blood stream. Consultation with a plastic surgeon or reconstructive
hand surgeon may be advisable.
WARNING
HAZARD: EXPLOSION OR FIRE – Solvent and paint fumes can explode or
ignite. Severe injury and/or property damage can occur.
Replaces
Part
Sheet
Part Sheet
77-5520R
77-5520R-1
Need help?
Do you have a question about the PitBull 1108-3500-2 and is the answer not in the manual?
Questions and answers