Panasonic CS-RE9SKUA Service Manual page 43

Hide thumbs Also See for CS-RE9SKUA:
Table of Contents

Advertisement

Replace the drain hose
Rear view for left piping installation
Drain hose
Drain cap
How to pull the piping and drain hose out, in case
of the embedded piping
Apply putty or
caulking material
to seal the wall
opening.
PVC tube for
drain hose (VP-20)
PVC tube
for drain
hose
Drain hose adapter 8 usage
Join indoor drain hose to 3/4"
(20 mm) nominal PVC pipe size
by using drain hose adapter 8
when necessary.
Remarks :
Make sure indoor unit drain hose
& 3/4" (20 mm) nominal PVC pipe
are fully inserted to drain hose
adapter 8.
Connection
cable
Adjust the piping
slightly downwards.
.
Connection
cable
Piping
PVC tube (VP-65) for piping
and connection cable
PVC tube for drain hose (VP-30)
Cable
Piping
Indoor unit
2
/
" (72 mm)
27
32
Drain hose
In case of left piping how to insert
the connection cable and drain hole.
Drain hose
from main unit
(For the right piping, follow the same
procedure)
Indoor unit
drain hose
3/4" (20 mm) nominal PVC pipe
- Install incline downward more than 1°
- Apply PVC glue at the join.
43
Connection
cable
Piping
More than 45
(1150 mm)
Drain hose
Sleeve for piping hole
Drain
hose
Cable
Piping
Close join by Vinyl Tape ( )
Drain hose adapter 8
9
/
"
32

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents