Panasonic CS-RE9SKUA Service Manual page 35

Hide thumbs Also See for CS-RE9SKUA:
Table of Contents

Advertisement

11.2.4
Connect the Cable to the Indoor Unit
1. The inside and outside connection cable can
be connected without removing the front grille.
2. Unscrew the conduit cover and fix the conduit
connector to conduit cover with lock nut, then
secure it against chassis.
3. Connection cable between indoor unit and
outdoor unit should be UL listed or CSA
approved 4 conductor wires minimum AWG16
in accordance with local electric codes.
Ensure the colour of wires of outdoor unit
o
and terminal number are the same as the
indoor's repectively.
Terminals on the indoor unit
Colour of wires (connection cable)
Terminals on the outdoor uni t
This equipment must be properly earthed.
Earth lead wire shall be Yellow/Green
o
(Y/G) in colour and shall be longer than
other lead wires as shown in the figure for
electrical safety in case of the slipping.
11.2.4.1
Wire Stripping, Connecting Requirement
Wire stripping
No loose strand
when inserted
RISK OF FIRE
JOINING OF WIRES
MAY CAUSE
WARNING
OVERHEATING
AND FIRE.
Do not joint wires
OR
1
2
3
1
2
3
WARNING
Indoor/outdoor
connection
terminal board
7/32" (5 mm)
or more
(gap between wires)
OR
Conduit
Connector
Lock Nut
Rear Side of Indoor Unit
Indoor and
outdoor
connection
cable
Conductor
fully inserted
ACCEPT
Use complete wire without joining.
Use approved socket and plug with earth pin.
Wire connection in this area must follow to
national wiring rules.
35
Conduit
Cover
Chassis
Terminal
Board
Earth wire
longer than
others
AC wires
for safety
reason
Holder
Conductor not
Conductor
fully inserted
over inserted
PROHIBITED
PROHIBITED
OR

Hide quick links:

Advertisement

Table of Contents
loading