Cool Mode Outdoor Air Temperature Characteristic - Panasonic CS-RE9SKUA Service Manual

Hide thumbs Also See for CS-RE9SKUA:
Table of Contents

Advertisement

20.9

Cool Mode Outdoor Air Temperature Characteristic

Condition
- Indoor room temperature: 80°F Dry Bulb/67°F Wet Bulb
- Unit setting: Standard piping length, forced cooling at 60.8°F, Hi fan
- Compressor frequency: Rated for cooling operation
- Piping length: 7.5m
- Voltage: 208/230V
20.9.1
CS-RE9SKUA CU-RE9SKUA
64.900
64.400
63.900
63.400
62.900
62.400
61.900
61.400
60.900
60.400
59.900
59.400
-4
3
10 17 24 31 38 45 52 59 66 73 80 87 94 101 108 115
5.200
4.620
4.040
3.460
2.880
2.300
-4
3
10 17 24 31 38 45 52 59 66 73 80 87 94 101 108 115
158.000
156.000
154.000
152.000
150.000
148.000
146.000
144.000
142.000
140.000
-4
3
10 17 24 31 38 45 52 59 66 73 80 87 94 101 108 115
Outdoor Air Temperature (°F)
Outdoor Air Temperature (°F)
Outdoor Air Temperature (°F)
120
208V/230V
208V
230V
208V/230V

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents