Piping Length Correction Factor - Panasonic CS-RE9SKUA Service Manual

Hide thumbs Also See for CS-RE9SKUA:
Table of Contents

Advertisement

20.11 Piping Length Correction Factor

The characteristic of the unit has to be corrected in accordance with the piping length.
20.11.1 CS-RE9SKUA CU-RE9SKUA CS-RE12SKUA CU-RE12SKUA
20.11.1.1 Cooling Capacity
1.04
1.02
1.00
0.98
0.96
0.94
0.92
20.11.1.2 Heating Capacity
1.06
1.04
1.02
1.00
0.98
0.96
0.94
0.92
0.90
Note: The graphs show the factor after added right amount of additional refrigerant.
2
3
4
5
6
(6.6)
(9.8)
(13.1)
(16.4)
(19.7)
Piping length
3 (9.8)
5 (16.4)
7.5 (24.6)
10 (32.8)
15 (49.2)
2
3
4
5
6
(6.6)
(9.8)
(13.1)
(16.4)
(19.7)
Piping length
3 (9.8)
5 (16.4)
7.5 (24.6)
10 (32.8)
15 (49.2)
7
8
9
10
11
(23)
(26.2)
(29.5)
(33)
(36.1)
Pipe Length (m/ft)
Capacity (kW)
1.0334
1.0213
1.0000
0.9855
0.9629
7
8
9
10
11
(23)
(26.2)
(29.5)
(33)
(36.1)
Pipe Length (m/ft)
Capacity (kW)
1.0593
1.0323
1.0000
0.9771
0.9536
128
12
13
14
15
16
(39.4)
(42.6)
(45.9)
(49.2)
(52.5)
12
13
14
15
16
(39.4)
(42.6)
(45.9)
(49.2)
(52.5)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents