Procedure 6.5 - Unit Does Not Mechanically Operate Freely/Quietly - Precor C842i Service Manual

Hide thumbs Also See for C842i:
Table of Contents

Advertisement

Procedure 6.5 - Unit does not Mechanically Operate
1.
Remove both covers per Procedure 7.1.
2.
If the unit is noisy, skip to step 8. If the unit does not turn freely continue with step 4.
3.
Remove the primary drive belt per Procedure 7.15.
4.
Remove the secondary drive belt per procedure 7.16.
5.
Turn the primary pulley, secondary pulley, idler pulley and alternator or generator by hand to
determine which part is not turning freely.
6.
Replace the necessary part(s) by following the appropriate procedure in Section Seven.
7.
Operate the unit and listen to the noise generated. The noise will be produced by one of the
following parts: primary pulley bearings, secondary pulley bearings, idler pulley, generator
or alternator.
8.
Replace the necessary part(s) by following the appropriate procedure in Section Seven.