Safe Handling - IDEAL Logic+ SYSTEM 15 User Manual

Table of Contents

Advertisement

intRodUCtion
The logic + System range of boilers are wall mounted, full
sequence, automatic spark ignition, low water content, fanned
flue, high efficiency, condensing, system gas boilers.
note. Due to the high efficiency of the boiler a plume of water
vapour will form at the terminal during operation.
Central heating (CH) output is fully modulating with a range of:
15
4.8 to 15kW (16,500 to 51,300 Btu/h)
18
4.8 to 18kW (16,500 to 61,600 Btu/h)
24
4.8 to 24.2kW (16,500 to 82,600 Btu/h)
30
6.1 to 30.3kW (20,700 to 103,300 Btu/h)
The boiler is supplied fully assembled with circulating pump,
pressure gauge, safety valve and CH expansion vessel.
A variable CH temperature control is fitted on the user control.
The boiler includes as standard:
-
Boiler frost protection
-
Daily pump exercise.
Note. The appliance must be wired with a permanent live supply,
or the boiler frost protection will not operate. The boiler warranty
will be invalid if this requirement is not complied with.
The boiler casing is of white painted mild steel.
The boiler temperature control is visibly located in the control
panel on the front of the boiler.
The heat exchanger is manufactured from cast aluminium.
The boiler is suitable for connection to fully pumped, sealed
heating systems ONLY. Adequate arrangements for completely
draining the system by provision of drain cocks MUST be provided
in the installation pipework.
Pipework from the boiler is routed downwards.
data Plate
The boiler model and serial number can be located on the bottom
of the boiler casing, shown in Frame 1 - Water & Gas Connection
Diagram.
oPeRAtion
When there is a demand for CH, the heating system is supplied at
the selected temperature of between 30
The boiler features a comprehensive diagnostic system which
gives detailed information on the boiler status when operating,
and performance of key components to aid commissioning and
fault finding.

SAfe HAndlinG

This boiler may require 2 or more operatives to move it to its
installation site, remove it from its packaging base and during
movement into its installation location. Manoeuvring the boiler
may include the use of a sack truck and involve lifting, pushing
and pulling.
Caution should be exercised during these operations.
Operatives should be knowledgeable in handling techniques when
performing these tasks and the following precautions should be
considered:
Grip the boiler at the base.
Be physically capable.
Use personal protective equipment as appropriate, e.g.
gloves, safety footwear.
During all manoeuvres and handling actions, every attempt should
be made to ensure the following unless unavoidable and/or the
weight is light.
8
general
o
o
C and 80
C.
Keep back straight.
Avoid twisting at the waist.
Avoid upper body/top heavy bending.
Always grip with the palm of the hand.
Use designated hand holds.
Keep load as close to the body as possible.
Always use assistance if required.
oPtionAl extRA KitS
Horizontal flue terminal (600mm long)
Horizontal flue terminal (1000mm long)
Horizontal Flue Telescopic
flue extension ducts (1000mm long)
flue extension ducts (2000mm long)
flue extension ducts (500mm long)
15-up to 9m
18-up to 9m
24-up to 9m
30-up to 8m
Elbow Kit (maximum per installation).
o
90
15-up to 6 elbows
18-up to 6 elbows
24-up to 6 elbows
30-up to 6 elbows
Elbow Kit (maximum per installation).
45
o
15-up to 6 elbows
18-up to 6 elbows
24-up to 6 elbows
30-up to 6 elbows
Roof flue Kit (to a maximum of 7.5m)
Powered Vertical Flue Kit (5m primary and 17m secondary
is a typical maximum length. For alternative details refer to
Powered Vertical Instructions)
Flue Finishing Kit
High Level Flue Outlet Kit
Flue Deflector Kit
Adjustable Flue Support Bracket
Balcony Flue Kit
Soffit Kit
Raised Horizontal Flue Outlet Kit
Concentric Flue Screw Retaining Kit
Weather Collar (Universal)
Weather Collar (Flat Roof)
Stand-Off Kit
Stand-Off Kit (inc. pipes)
Pre-Piping Frame Kit
Condensate Pump Kit
Weather Compensation Kit
Security Bracket Kit
PRV Wall Outlet Kit
Pressure Gauge Extension Kit
Ideal Logic + System -
Installation and Servicing

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents