GENERAL VENT
MAINTENANCE
Conduct an inspection of the venting system semi-
annually. Recommended areas to inspect as follows:
1) Check the Venting System for corrosion in areas
that are exposed to the elements. These will
appear as rust spots or streaks, and in extreme
cases, holes. These components should be
replaced immediately.
2) Remove the Cap, and shine a flashlight down the
Vent. Remove any bird nests, or other foreign
material.
3) Check for evidences of excessive condensation,
such as water droplets forming in the inner
liner, and subsequently dripping out the joints,
Continuous condensation can cause corrosion
of caps, pipe, and fittings. It may be caused
by having excessive lateral runs, too many
elbows, and exterior portions of the system
being exposed to cold weather.
4) Inspect joints, to verify that no pipe sections or
fittings have been disturbed, and consequently
loosened. Also check mechanical supports such
as Wall Straps, or plumbers' tape for rigidity.

LOG REPLACEMENT

The unit should never be used with broken logs. Turn
off the gas valve and allow the unit to cool before
opening door and carefully remove the logs. (The
pilot light generates enough heat to burn someone.)
If for any reason a log should need replacement, you
must use the proper replacement log. The position
of these logs must be as shown in the diagrams
under Log Installation.
Note: Improper positioning of logs may create
carbon build-up and will severely alter the
unit's performance which is not covered
under warranty.
THERMOPILE/
THERMOCOUPLE
1) Remove faceplate, safety screen and glass
door.
2) Remove Logs and burner (if installed).
3) Remove rear log tray by removing 2 screws.
4) Remove pilot assembly by removing 2 screws.
5) Pull pilot assembly up slightly and loosen the
thermocouple or thermopile with a 7/16" wrench.
6) Loosen the thermocouple or thermopile with a
7/16" wrench.
7) Disconnect thermocouple by loosening nut
from the valve with a 9mm wrench. Disconnect
thermopile by loosening 2 screws marked TP
on the valve.
8) Drop the thermocouple or thermopile down from
the bracket and pull it out of the unit.
9) Reinstall the new ones in reverse order.

GLASS GASKET

If the glass gasket requires replacement with a
tadpole glass gasket for the Flush Front (Part #
936-155).
DOOR GLASS
Your Regency
fireplace is supplied with high
®
temperature, 5 mm Neoceram ceramic glass that will
withstand the highest heat that your unit will produce.
If your glass requires cleaning, we recommend
using an approved glass cleaner available at all
authorized dealers. Do not use abrasive materials.
Do not clean the glass when hot.
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency
dealer only, and follow our step-by-step
®
instructions for replacement.
Regency
maintenance
WARNING: Do not operate the
appliance with the glass panels
removed, cracked or broken.
Replacement of the glass panels
should be done by a licensed or
qualified service person.
Caution: Wear gloves when removing
damaged or broken glass.
Flush Glass Replacement
Remove the flush door front. Remove the 4 glass
clips from each corner. Slide in the new replacement
glass. Push the 4 glass clips back onto the frame.
The glass must have gasketing around it.