 Precautions in handling the antifreeze liquid
• Be sure to wear goggle and gloves for handling
the antifreeze liquid.
• Use the recommended antifreeze liquid(SPC-
0394) by Mimaki. If not, the cooling device may be
broken. (Supplied antifreeze liquid :1000cc x 2
bottles)
• Do not touch the antifreeze liquid directly. If the
antifreeze liquid settles on your skin or clothes,
immediately wash it off with soap and water. If you
get antifreeze liquid in your eyes, immediately
wash your eyes with a lot of clean water. Then,
consult a doctor as soon as possible.
• Store antifreeze liquid in a dark and cold place.
• Store antifreeze liquid in a place that is out of the
reach of children.
• When discarding antifreeze liquid which is no
longer needed, entrust them to an industrial waste
disposal contractor, clarifying their contents.
• Before using antifreeze liquid, be sure to read the
Material Safety Data Sheet (MSDS).
• Prepare a tank with a cap to put in the waste water
from cooling water tank.
• When water in the cooling water tank is low, a
warning message "WATER LACK" is displayed. In
this case, refill antifreeze water in the way shown
as the next page.

Refill antifreeze mixed water

If an error of lack of water, refill antifreeze mixed water.
1
Uncover the feed-water inlet and the air
vent.
feed-water inlet
air vent cover
2
Remove all remaining water in the tank.
(1) Remove all water in the tank with a provided
syringe from the feed-water inlet.
(2) Put the removed water into the tank with a
cap, and discard it.
3
Made mixed water (antifreeze liquid: 1,
water: 2) in the attached reservoir and
move it to the attached syringe.