Control / Function / Operation - Wolf CGB-75 Assembly And Operating Instructions Manual

Gas condensing boiler
Table of Contents

Advertisement

ON/OFF switch
0
I
6

Control / Function / Operation

Reset
button
temperature
Illuminated
signal ring
ON/OFF switch
The condensing boiler is OFF in position 0.
Reset
A fault is reset by pressing the reset button which will also restart the system.
Pressing the reset button reactivates the system, if there was no fault.
Illuminated signal ring as status indicator
Display
Flashing green
Constant green light
Flashing yellow
Constant yellow light Burner ON; flame steady
Flashing red
DHW temperature selection.
When gas condensing boilers are combined with a DHW cylinder, setting 1-9 corresponds
to a cylinder temperature of 15-65 °C. The DHW temperature selector setting becomes
ineffective when the system is combined with a digital room thermostat or a weather-
compensated controller. The temperature will then be selected at the controller
(accessory).
Heating water temperature selection.
Settings 2-8 correspond, when factory-set, to a heating water temperature of 20-80 °C.
The heating water thermostat setting becomes ineffective when the system is combined
with a digital room thermostat or a weather-compensated controller.
DHW
selector
Heating water
temperature
selector
Explanation
Standby (power supply ON; no heat demand)
Heat demand: Pump running; burner OFF
Emissions test mode
Fault
Thermometer