Illuminated status indicator ring
Illuminated ring
Flashing green
Constant green light
Flashing yellow
Constant yellow light
Flashing red
Summer mode
Winter mode
Emissions test mode
DHW temperature selector
Heating water temperature selector
Note:
6

Control unit operation

ON/OFF
switch
Explanation
Standby (power supply ON, burner OFF, e.g. summer mode)
Winter mode: Pump running, burner OFF
Emissions test mode
Burner operating flame ON
Fault
The BM programming module can also be integrated into the control unit.
That means that all settings are made at the MGK. For installation and
operation, see the BM programming module operating instructions.
Heating water
Reset button
temperature selector
Illuminated
DHW
ring
temperature
selector
(central heating OFF)
Setting 2 to 8
(indicator ring flashes yellow)
1 (15 °C) ... 9 (65 °C)
2 (20 °C) ... 8 (75 °C)
Thermometer
Pressure gauge
7 (55 °C) recommendation
3062881_0910