Design Information - Wolf CGB-75 Assembly And Operating Instructions Manual

Gas condensing boiler
Table of Contents

Advertisement

Balanced flue routing
Versions
B23
Flue in a duct and combustion air
directly via the boiler (open flue)
B23
Two-boiler cascade flue in a duct and
combustion air directly via the boiler (open flue)
B33
Flue in a duct with horizontal
concentric connection pipe (open flue)
B33
Connection to a moisture-resistant flue chimney with horizontal
concentric connection pipe (open flue)
C13x Horizontal concentric roof outlet through a pitched roof,
(balanced flue - on-site dormer)
C33x Vertical concentric roof outlet through a pitched roof
or flat roof (balanced flue)
C43x Connection to a moisture-resistant balanced flue chimney (LAS flue )
Maximum pipe length from the centre of the boiler bend to the connector 2 m
(balanced flue)
c53
Connection to the flue in a duct
and ventilation air line through an external wall (balanced flue)
C53x Connection to a flue on an external wall (balanced flue)
C83x Connection to the flue in a duct and
ventilation air through an external wall (balanced flue)
C83x Concentric connection to a moisture-resistant flue gas chimney and
combustion air through an external wall (balanced flue)
C93x Vertical flue for installation in a duct, rigid/flexible
with horizontal concentric connection line
Available fan draught: CGB-75 145 Pa, CGB-100 200 Pa
1)
(The maximum length corresponds to the total length from the appliance to the flue terminal)
Expansion in the duct from DN 110 to DN 160
2)
Note: Systems C33x and C83x are also suitable for installation in garages.
Where necessary, adapt the installation examples to the relevant Building Regulations and requirements of your country/region.
Discuss any questions relating to the installation of inspection covers and ventilation apertures with your local flue gas inspector.
The length dimensions for a concentric balanced flue and flues relate exclusively to original Wolf components.
3062555_201507

Design information

Maximum length
CGB-75
DN 110
23
DN 110/160
50
2)
DN 110
45
DN 110
23
DN 110/160
50
2)
Calculation according to EN 13384
(balanced flue manufacturer)
DN 110/160
14
DN 110/160
14
Calculation according to EN 13384
(balanced flue manufacturer)
DN 110
23
DN 110/160
50
2)
DN 110
15
DN 110
23
DN 110/160
50
2)
Calculation according to EN 13384
(balanced flue manufacturer)
DN 110
14
DN 110/160
45
2)
[m]
1)
CGB-100
23
50
23
23
50
14
14
23
50
15
23
50
14
39
41