1)
Pull out the plug  (undo the cross-head screws first)
2)
Undo the threaded gas connection on the gas combination
valve
3)
Unscrew the mixing chamber from the fan (3-off hex socket
head screws, 5 mm); pull off the air inlet pipe if necessary
4)
4-off screws
8 AF
Unscrew the gas combination valve from the mixing
chamber for gas/air (4 screws, 8 AF).
24
Conversion to liquefied petroleum gas P
(G31) (if necessary)
5)
6)
7)
Mixing chamber
Gas restrictor
Threaded gas
connector
4-off screws, 8 AF
Remove the four 8 AF screws from the threaded gas
connector and remove the threaded connector from the
gas combination valve.
Remove the gas combination valve and the gas restrictor.
Attach the protective labels on the inlet and outlet of the
new gas combination valve to the openings of the removed
valve.
O-ring 23.47 x 2.62
Gas restrictor 6.7
Gas combination
valve
Threaded gas
connector
Screw the threaded gas connector with O-ring 26 x 4 onto
the new gas combination valve for LPG.
Insert the new gas restrictor with the ID 6.7 into the gas
combination valve.
Screw the gas combination valve with O-ring 23.4 x 2.6
onto the mixing chamber.
O-ring
Gas combination
valve
Threaded gas
connector
Adhere the O-ring in the sealing groove of the fan with
silicone grease and mount the mixing chamber with gas
combination valve on the burner fan.
Tightly screw the threaded gas connector to the gas supply
pipe.