Display
Cause
Power OFF/ON
Video error.
Is the CU/PU board installed
073 : Error **
An error was
properly?
detected in
expanding
image data (an
invalid data
was received)
Does the error occur again?
Is the CU/PU board installed
properly?
Does the error occur again?
Does the error depend on
print data?
Power OFF/ON
Video error.
Is the CU/PU installed
074 : Error
An error was
properly?
075 : Error **
detected in
expanding
image data.
Inspection is
Parameter
Reading from or writing into
required.
matching
EEPROM or flash memory
081 : Error
check error
cannot be made properly.
Inspection is
An engine
required.
EEPROM
104 : Error
read/write
Does the error occur again?
error was
detected.
Inspection is
Engine control
required.
logic error
106 : Error
Does the error occur again?
44473001TH Rev.1
Error details
Measure
No
Reinstall it properly.
Yes
Change the PC to a
high-specification one
or decrease the
resolution, and
perform printing again.
Yes
Replace the CU/ PU
board.
Replace the interface
cable.
Reinstall the PC
printer driver.
No
Reinstall it properly.
Yes
Perform printing
again.
Yes
Print other data.
No
Replace the CU/PU
board.
Yes
Ask design people to
analyze the data.
No
Reinstall it properly.
Yes
Replace it.
Turn off and on the
MFP.
Replace the CU/PU
board when the
symptom persists.
Turn off and on the
MFP
Yes
Replace the CU/PU
board.
Turn off and on the
MFP
Yes
Replace the CU/PU
board.
Display
Cause
Inspection is
The 2nd tray
Is the 2nd tray for the MFP
required.
for a model
installed?
112 : Error
different from
the MFP was
detected.
Inspection is
High-voltage
Is the cable between the CU/
required.
power supply
PU board and the high-
121 : Error
interface error
voltage power unit connected
properly?
Is a contact faulty?
Inspection is
Rear-fan error
Does the fan at the rear of
required.
the MFP operate?
122 : Error
Is the connector of the fan
connected properly?
Inspection is
Ambient
Is the cable from the CU/PU
required.
humidity
board to the toner sensor
123 : Error
error or non
board connected properly?
connection
of humidity
sensor
Inspection is
Ambient
Is the cable from the CU/PU
required.
temperature
board to the toner sensor
124 : Error
error
board connected properly?
Inspection is
Image drum
Is the connector of the fan
required.
fan error
connected properly?
128 : Error
Does the error occur again?
05
Inspection is
Front fan error
Is the connector of the fan
required.
connected properly?
128 : Error
Does the error occur again?
08
7. TROUBLESHOOTING PROCEDURES
Error details
Measure
No
Install proper 2nd tray.
No
Reconnect it properly.
Check the high-
Yes
voltage line for no
poor connection.
No
Replace the high-
voltage power supply.
No
Be sure of the
connection of the
fan.
Yes
Replace the CU/PU
board.
No
Connect the fan
properly.
Yes
Replace the CU/PU
board.
No
Re-connect it properly.
Yes
Replace the toner
sensor board.
No
Re-connect it properly.
Yes
Replace the toner
sensor board.
No
Re-connect it properly.
Yes
Replace the fan motor.
No
Replace the CU/PU
board.
No
Re-connect it properly.
Yes
Replace the fan motor.
No
Replace the CU/PU
board.