Bosch ALB 36 LI Original Instructions Manual page 6

Cordless leaf blower
Table of Contents

Advertisement

OBJ_BUCH-2071-003.book Page 6 Wednesday, November 20, 2013 11:09 AM
6 | English
Battery Charged
AL 3640 CV
Professional
AL 3620 CV
Professional
Continuous lighting of the green charge control LED sig-
nals that the battery is fully charged.
Additionally, a signal tone sounds for approx. 2 seconds,
which acoustically indicates that the battery is fully charged.
Afterwards, the battery can be removed for immediate use.
With no battery inserted, continuous lighting of the green
charge control LED indicates that the mains plug is plugged
into the socket and that the battery charger is ready for oper-
ation.
Battery Temperature below 0 °C or above 45 °C
AL 3640 CV
Professional
AL 3620 CV
Professional
Continuous lighting of the red LED indicates that the battery
temperature is not within the rapid-charging temperature
range of 0 °C – 45 °C. As soon as the allowable temperature
range is reached, the battery charger automatically switches
to rapid charging.
When the battery is not within the allowable temperature
range, the red battery LED lights up when inserting the bat-
tery into the battery charger.
No charging procedure possible
AL 3640 CV
Professional
AL 3620 CV
Professional
If a different malfunction of the charging procedure is pre-
sent, this will be indicated through flashing of the red charge
control LED.
The charging procedure cannot be started and the battery
cannot be charged (see section "Troubleshooting").
F 016 L70 963 | (20.11.13)
Charging Advice
With continuous or several repetitive charging cycles without
interruption, the charger can warm up. This is not meaningful
and does not indicate a technical defect of the battery charg-
er.
A significantly reduced working period after charging indi-
cates that the battery is used and must be replaced.
Observe the notes for disposal.
Battery Cooling (Active Air Cooling)
The fan control integrated in the battery charger controls the
temperature of the inserted battery. When the battery tem-
perature is above 30 °C, a fan cools down the battery to the
optimal charging temperature. The switched-on fan produces
a fan noise.
The battery temperature is within the optimal charging tem-
perature range when the fan is not running. Another reason
for a non working fan might be that it is defective. In this case,
the charging time of the battery might be extended.
Battery Charge-control Indication
The battery charge-control indicator consists of three green
LEDs, and indicates the charge condition of the battery for a
few seconds when the On/Off switch is pressed halfway or
fully.
LED
Continuous lighting 3 x green
Continuous lighting 2 x green
Continuous lighting 1 x green
Flashing light 1 x green
Working Advice
When operating, always hold the machine approximately
3 cm above the ground.
Do not blow hot, flammable or explosive material.
Capacity
≥ 2/3
≥ 1/3
< 1/3
Reserve
Bosch Power Tools

Advertisement

Table of Contents
loading

Table of Contents