Random Auto Restart Control; Delay On Timer Control; Remote Control Signal Receiving Sound - Panasonic CS-MA95KE Service Manual

Room air conditioner
Hide thumbs Also See for CS-MA95KE:
Table of Contents

Advertisement

8.5.
Sleep Mode Auto Operation
Cooling or Soft Dry Operation
When you press the SLEEP Mode, the following movement will
start to avoid overcooling.
• The fan speed refer to Indoor Fan Motor Control.
• The setting temperature will be risen by 0.5°C at the start of
operation and by 0.5°C one hour later.
• The operation will stop after 8 hours.
• When using together with the Timer, the ON-Timer has
priority.
Heating Operation
When you press the SLEEP Mode, the following movement will
start to avoid overheating.
• The fan speed refer to Indoor Fan Motor Control.
• The setting temperature will be decrease by 2°C at the start
of operation and by 3°C one hour later.
• The operation will stop after 8 hours.
• When using together with the Timer, the ON-Timer has
priority.
8.6.

Random Auto Restart Control

• If there is a power failure, operation will be automatically restarted after 3 to 51/2 minutes when the power is resumed. It will
start with previous operation mode and airflow direction.
• Restart time is decided randomly using 4 parameter:
Intake air temperature, setting temperature, fan speed and Air Swing Blade position.
• Random Auto Restart Control is not available when Timer or Sleep Mode is set.
• This control can be omitted by open the circuit of JX1. (Refer Circuit Diagram)
8.7.

Delay ON Timer Control

• When the Delayed ON Timer is set by using the remote control, the unit will start operate slightly before the set time, so that
the room will reach nearly to the set temperature by the desired time.
• For Cooling and Soft Dry mode, the operation will start 15 minutes before the set time.
• For Heating mode, the operation will start 30 minutes before the set time.
• For Automatic mode, the indoor fan will operate at Lo speed for 25 seconds, 30 minutes before the set time to detect the intake
air temperature to determine the operation mode. The operation indication lamp will blink at this time.
8.8.

Remote Control Signal Receiving Sound

• Long beep sound will be heard when:-
− Stopping the Air Conditioner using ON/OFF switch.
− Stopping the Sleep Mode.
− Stopping the Powerful Mode.
− Stopping the Economy Mode.
• Short beep sound will be heard for others.
• To switch off the beep sound:-
Press the "Automatic Operation Button" continuously for 10 seconds or more ("beep" "beep" will be heard at the 10th second).
Repeat the above if you want to switch ON the beep sound or switch OFF the power switch at the indoor unit and switch it ON
again.
However, if the "Automatic Operation Button" has been pressed the Automatic cooling operation will be activated.
If you do not require this operation, you may change it by using the remote control.
CS-MA95KE CU-MA185KE / CS-MA125KE CU-MA245KE / CS-MA75KE / CS-MA125KE CU-MA195KE
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-ma125keCu-ma185keCu-ma195keCu-ma245keCs-ma75ke

Table of Contents