Panasonic CS-MA95KE Service Manual page 9

Room air conditioner
Hide thumbs Also See for CS-MA95KE:
Table of Contents

Advertisement

Compressor
Motor
Rated
Air Circulation
Motor
Rated
Fan Speed
Heat Exchanger
Description
Tube material
Fin material
Fin Type
Row / Stage
FPI
Size (W × H × L)
Refrigerant Control Device
Refrigeration Oil
Refrigerant (R-22)
Thermostat
Protection Device
Capillary Tube
Length
Flow Rate
Inner Diameter
Air Filter
Material
Style
Capacity Control
Compressor Capacitor
Fan Motor Capacitor
• Specifications are subject to change without notice for further improvement.
CS-MA95KE CU-MA185KE / CS-MA125KE CU-MA245KE / CS-MA75KE / CS-MA125KE CU-MA195KE
Type
Type
Output
W
Type
Material
Type
Input
W
Output
W
Low
rpm
Medium
rpm
High
rpm
SuperHigh
rpm
mm
(c.c)
g (oz)
mm
l/min
mm
(c.c)
µF, VAC
µF, VAC
Cross-flow Fan
AS + Glass Fiber 30%
Induction (4-poles)
29.0 - 27.5
(1 unit) 20 (2 units) 20 × 2
875 - 800
1025 - 965
1250 - 1210
1330 - 1310
Evaporator
Copper
Aluminium
Slit Fin
(Plate fin configuration, forced draft)
2 × 14
18
614 × 294 × 25.4
Electronic Control
P.P.
Honeycomb
Capillary Tube
1.0 µF, 400VAC
9
Rotary (1 cylinder)
rolling piston type
Induction (2-poles)
(1 unit) 750 (2 units) 750 × 2
Propeller Fan
AES + Glass Fiber 12%
Induction (6-poles)
65.8 × 2 - 50.5 × 2
(1 unit) 20 (2 units) 20 × 2
695 - 635, 755 - 705
Condenser
Copper
Aluminium
Corrugated Fin
1 × 18
19
856 × 457.2 × 22
Capillary Tube
SUNISO 4GDID or ATMOS M60
(350 × 2)
890 × 2 (31.4 × 2)
Overload Protector
Cooling; 1,033, Heating; 585
Cooling; 4.8, Heating; 9.9
Cooling; 1.2, Heating; 1.4
25 µF, 370VAC
(Upper unit) 1.0 µF, 400VAC
(Lower unit) 1.2 µF, 400VAC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-ma125keCu-ma185keCu-ma195keCu-ma245keCs-ma75ke

Table of Contents