Panasonic CS-MA95KE Service Manual page 4

Room air conditioner
Hide thumbs Also See for CS-MA95KE:
Table of Contents

Advertisement

CS-MA95KE CU-MA185KE / CS-MA125KE CU-MA245KE / CS-MA75KE / CS-MA125KE CU-MA195KE
Indoor Unit
AUTO
OFF / ON
Automatic Operation Button
• Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be used.)
• Press continuosly for 5s or < 10s to
operate Test Run/Pump down. "Beep"
sound will be heard at the 5th second.
(Used when test running or servicing.)
• Press continuosly for 10s and above to
omit or resume the remote control signal
receiving sound. "Beep, beep" sound will
be heard at the 10th second.
Operation Indication Lamps (LED)
POWER
(Orange) ........ Lights up in Sleep
SLEEP
(Orange) ....... Lights up in Timer
TIMER
POWERFUL
ECONOMY
Operation Mode
• Heating, Cooling, Soft Dry and
Automatic Mode.
Powerful Operation
• Reaches the desired room temperature
quickly.
Economy Operation
• To reduce electrical power consumption.
Random Auto Restart Control
• Operation is restarted randomly after
power failure at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
(Green) ........ Lights up in operation,
blinks in Automatic
Operation Mode
judging.
Mode Operation.
Setting.
(Orange) .. Lights up in Powerful
Mode Operation.
(Green) ..... Lights up in Economy
Mode Operation.
Sleep Mode Auto Control
• Indoor Fan operates at Low speed.
• Operation stops after 8 hours.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
– Heating : Fan speed varies from ME
– Cooling : Fan rotates at Hi and Me
– Soft Dry: Fan rotates at Lo speed.
Airflow Direction Control
• Automatic air swing and manual adjusted
by remote control for vertical airflow.
• Manually adjusted by hand for horizontal airflow.
Starting Current Control
Time Delay Safety Control
• Restarting is inhibited for appro. 3 minutes.
7 Minutes Time Save Control
• Cooling Operation only.
30 Minutes Time Save Control
• Heating Operation only.
Hot-Start Control
• At Heating Operation the indoor fan will
operate at Lo speed when indoor heat
exchanger temperature reaches 30°C.
Anti Cold Draft Control
• The indoor fan operates at SSLo when the
indoor heat exchanger temperature is low.
4
; Lo in accordance with
indoor heat exchanger.
speed. Deodorizing control
is available.
Deodorizing control
is available.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-ma125keCu-ma185keCu-ma195keCu-ma245keCs-ma75ke