Symbol Ms1204Fzy Technical Specifications - Symbol MINISCAN MSXX04 Integration Manual

Miniscan msxx04 series
Table of Contents

Advertisement

Symbol MS1204FZY Technical Specifications

Table 4-2
provides the Symbol MS1204FZY technical specifications.
Symbol MS1204FZY Technical Specifications @ 23°C
Table 4-2
Item
Power Requirements
Input Voltage
Scanning Current
Standby Current
V
Noise Level
cc
Laser Power
Scan Rate
Print Contrast
Scan Angle
Scan Pattern
Skew Tolerance
Pitch Angle
Roll
Decode Depth of Field
Ambient Light Immunity
Sunlight
Artificial Light
Drop
Vibration
ESD
Sealing
Operating Temperature
Storage Temperature
Humidity
Note: Environmental and/or tolerance parameters are not cumulative.
5.0 VDC ±10%
160 mA ±40 mA
20 mA ±5 mA typical
200 mV peak-to-peak max.
1.0 mW ± 0.12 mW, λ = 650 nm nominal
36 (± 5) scans/sec (bidirectional)
Minimum 25% absolute dark/light reflectance measured at 650 nm.
Default (Wide): 42° ± 2°
Alternate (Narrow): 30° ± 2°
Single scan line
± 50° from normal (see
Figure 4-4 on page
± 65° from normal (see
Figure 4-4 on page
± 20° from vertical (see
Figure 4-4 on page
See
Figure 4-5 on page 4-7
8,000 ft. candles (86,112 lux)
450 ft. candles (4,844 lux)
Multiple 30" drops
Unpowered scanner withstands a random vibration along each of the
X, Y and Z axes for a period of one hour per axis, defined as follows:
20 to 80 Hz
Ramp up to 0.04 G^2/Hz at the rate of 3dB/octave.
80 to 350 Hz
0.04 G^2/Hz
350 to 2000 Hz
Ramp down at the rate of 3 dB/octave.
± 20kV air discharge
± 8kV indirect discharge
IP54
-4° to 122°F (-20° to 50°C)
-40° to 158°F (-40° to 70°C)
5% to 95% non-condensing
Symbol MS1204FZY Specifications