10 - 18 Symbol MiniScan MSXX04 Series Integration Guide

Timeout Between Decodes

Timeout Between Decodes, Same Symbol
Parameter # 89h
When in Continuous triggering mode, this parameter sets the minimum duration of not decoding data before the
scanner decodes a second bar code identical to one just decoded. This reduces the risk of accidently scanning the
same symbol twice. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds. The recommended
interval is 0.6 seconds.
Timeout Between Decodes, Different Symbol
Parameter # 90h
This option sets the minimum duration of not decoding data before the scanner decodes a second (different) bar
code. This is used in continuous-on mode to prevent the beeper from beeping when a different symbol appears in
the scanner's field of view before the timeout period between decodes expires. This is programmable in 0.1 second
increments from 0.0 to 9.9 seconds. The recommended value is 0.0 seconds.
Select the timeouts between decodes for the same or different symbols.
Scan the option bar code you wish to set.
1.
Scan two numeric bar codes beginning on
2.
increments.
To change the selection or to cancel an incorrect entry, scan the
page 10-111
which correspond to the desired interval, in 0.1 second
Cancel
Timeout Between Decodes -
Same Symbol
Timeout Between Decodes -
Different Symbols
bar code on
page
10-113.