Scan Angle Selection; Selecting Scan Angle Via Ssi; Selecting Scan Angle Via Parameter Bar Code; Operation In Blink Mode - Symbol MINISCAN MSXX04 Integration Manual

Miniscan msxx04 series
Table of Contents

Advertisement

3 - 4
Symbol MiniScan MSXX04 Series Integration Guide
Omnidirectional Scan Pattern
The high-speed rotating omnidirectional scan pattern provides aggressive performance on 1D bar codes because
there are no "holes" in the pattern. This ensures fast throughput at the point of activity and the ability to read 1D
o
symbols in 360
of rotation, eliminating the need to orient the bar code in the field of view.
Omnidirectional Scan Pattern
Figure 3-6
High Density Single Scan Line Scan Pattern
The high density single scan line appears as a "mini" raster and scans multiple areas of
1D codes to swiftly and accurately capture data on poorly printed and damaged bar codes.
High Density Single Scan Line Scan Pattern
Figure 3-7

Scan Angle Selection

The Symbol MS1204FZY and MS954 scanners support two pre-set scan angles (see each scanner's technical
specifications)
.

Selecting Scan Angle via SSI

To use SSI to select the scan angle, issue the SSI PARAM_SEND command with the NUM_SCAN_ANGLE (191)
parameter number. This is set to the default angle (182), or can be set to the alternate angle (181). See the Simple
Serial Interface (SSI) Programmer's Guide (p/n 72-40451-xx) for more information.

Selecting Scan Angle via Parameter Bar Code

The scan angle can also be set by scanning a parameter bar code (see
parameter bar code is scanned, that scan angle setting is retained.

Operation in Blink Mode

The scan angle during Blink Mode is determined by the scan angle system parameter.
Scan Angle on page
10-12). Once the

Advertisement

Table of Contents
loading

Table of Contents