D. Blower Replacement
1. The grille on the blower access assembly is hinged.
Swing the grille downward to expose the 2 screws.
Figure 8.1
2. Remove the 2 screws from the blower access assembly
and slide assembly away from the appliance.
3. Disconnect the wires from the blower.
4. Remove the 2 screws from the hold down bracket and
pull the blower and bracket forward.
5. Remove the blower from the hold down bracket.
6. Remove the protection guards from each end of the
blower.
7. Re-install in reverse order. Be certain that the hold down
bracket's screws are completely seated in the grom-
ments. Insert the locating tab in the hold down bracket
into the placement slot.
CAUTION! Unplug appliance
from power source before
replacing any components.
Blower Access
Grille hinges
downward
Remove Screws &
Pull Access Assembly
away from Insert
Figure 8.1
Page 12
Assembly
Hold Down
Bracket
Shock Risk
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front of appliance.
Fire Risk
Do NOT allow hot coals or embers to overfl ow ash lip
May melt protective wire coating on fan power
cord causing electrical short, fi re or injury
Placement Slot
Remove Screws from Hold
Down Bracket and Pull
Forward